Pure Sine Wave, Bi-Directional

Microcare Inverters have been made in South Africa for the last 20 years. During this period J&J has manufactured and sold thousands of inverters locally and internationally. The technology has been upgraded and the current range of inverters use High Frequency Pulse Width Modulation (PWM) to regulate the output of the inverter. The updated circuitary allows for smaller units and more cost effective quality performance. The inverters are pure sine wave with very low distortion and good regulation. The units incorporate battery low, overload, lightning protection, load sensing and LCD display as standard. Service and repair of the inverters at a minimum cost due to local manufacture.
Features:
- Available for 12v/24v/36v/48v and 96v dc systems
- Output power from 1kw – 10kw
- LCD Display
- Low idle current
- High Surge capacity for motor start
- Timed Overload capacity with Auto-Shutdown
- 3 Attempt Auto Restart
- Protection against short circuits
- Built in battery charger
- Locally manufactured
- Minimum Service Turnaround
- Fan cooling for optimum performance
- Audible Buzzer indicating faults and overload conditions
- 3 Year Warranty
|
Details |
1kw |
2kw |
3kw |
5kw |
||||
|
|
Model no |
mcin-1kw-12/24/36/48 |
mcin-2kw-12/24/36/48 |
mcin-3kw-24/36/48 |
mcin-5kw-36/48 |
|||
|
OUTPUT |
AC Voltage |
230v |
230v |
230v |
230v |
|||
|
|
AC Amps |
5 |
10 |
15 |
25 |
|||
|
|
Rated Power |
1000w |
2000w |
3000w |
5000w |
|||
|
|
Charger Amps |
40/30/20/10 |
40/30/20 |
60/40/30 |
75/50 |
|||
|
|
Low Idle Current |
15 watts |
25 watts |
40 watts |
60 watts |
|||
|
|
Surge Power |
200% |
||||||
|
|
Waveform |
Sine Wave |
||||||
|
|
AC Regulation |
±3% |
||||||
|
|
THD |
< 3% |
||||||
|
|
Frequency |
50Hz±1% |
||||||
|
|
Display |
LCD |
||||||
|
INPUT |
DC Voltage |
12/24/36/48 |
12/24/36/48 |
24/36/48 |
36/48 |
|||
|
|
DC Amps Max |
100/50/33/25 |
200/100/66/50 |
150/100/75 |
180/125 |
|||
|
|
Voltage Range |
10v-14v / 20v-32v / 30v-48v / 40v-60v / |
||||||
|
|
Efficiency(typical) |
<92% |
||||||
|
|
DC Connector |
Battery Cables |
||||||
|
|
Fuse |
Internal Fuses |
||||||
|
PROTECTION |
Batt Low Alarm |
Yes |
||||||
|
|
Batt Low Shutdown |
Yes |
||||||
|
|
Over Load |
120%/3min 150%/1min 200%/30sec |
||||||
|
|
Over Voltage |
Auto Shutdown |
||||||
|
|
Over Temperature |
Auto Shutdown and Reset |
||||||
|
|
Output Short |
Auto Shutdown and 3 attempt Reset |
||||||
|
|
Cooling |
Fan controlled |
||||||
|
ENVIRONMENT |
Working Temp |
0-40° |
||||||
|
BUILT IN BATTERY CHARGER |
||||||||
Specifications
All Microcare Products have a 3 year carry in warranty